Rubber Expansion Joints for 3rd Desalination plant at Tuas (TDP3)

Rubber Expansion Joints for 3rd Desalination plant at Tuas (TDP3)

Detailed

3rd Desalination plant at Tuas (TDP3)

Location: Singapore

Terms of Delivery: CIF Singapore

Products: Rubber Expansion Joints

Item list:

Size from DN80 to DN1600, 165pcs in total.


Project Information

The objective of this Technical Specification is to define the minimum requirements for developing the detailed engineering, manufacture, supply of material, testing, packing, delivery, assembly and commissioning of the valves for the construction of the 3rd Desalination plant at Tuas (TDP3), Singapore.

Supplier shall apply good Practice, acting in good faith to perform obligations in accordance with the requirements of the Law and international Good Practice in the electricity and desalination industries commonly used in prudent engineering and operation to design, engineer, construct, test, operate and maintain equipment lawfully, safely and economically as applicable to desalination facilities of the size, service, and type as the Plant.

TDP3 will occupy a plot of land (fronting Tuas South Avenue 3), which currently separates the SingSpring and Tuaspring desalination plants.rubber expansion joint location

CLIMATIC CONDITIONS

Temperatures



Maximum ambient temperature in the shade, to be taken as air inlet temperature for air-conditioning and ventilation

40

°C

Minimum ambient temperature

20

°C

Average annual ambient air temperature

30

°C

Maximum metal temperature in the sun

85

°C

Barometric Pressure



Maximum barometric pressure

1030

mbar

Minimum barometric pressure

970

mbar

Humidity



Maximum ambient relative humidity

100

%

Average annual ambient relative humidity

90-95

%

Minimum ambient relative humidity

50

%

Annual Rainfall



Maximum rainfall during 15 minutes

12

mm

Total rainfall during 2012 and 2013

124

mm

Wind



Maximum wind velocity

>140

km/h

Design wind velocity

120

km/h

Dust concentration



Dust concentration in the air under normal conditions

1.0–2.0

mg/m3

Dust concentration in the air approx. under dust storm conditions

100

mg/m3

Seismic Activity

Not apply


SEAWATER CONDITIONS

Feed water for the 3rd Desalination Plant at Tuas (TDP3) will be open intake seawater from the Straits of Johor.

Temperature range 26°C – 32°C

Sea water analysis is typically as follows:

Parameter

Unit

HistoricalSeawater Data

DesignRange

AddoptedDesign ions

Mean

95%ile

Maximum

  Ca2+

mg/l

357.00

429.00

768.00

<=500

500.00

  Mg2+

mg/l

1,131.00

1,388.00

1,580.00

<=1,400

1,400.00

  Na+

mg/l

9,254.00

10,875.00

11,600.00

<=11,500

10,410.85

  K+

mg/l

348.00

411.00

436.00

<=420

420.00

  Sr2+

mg/l

5.90

7.20

7.30

<=7.3

7.30

  Ba2+

mg/l

0.07

0.10

0.10

<=0.1

0.10

  NH4+

mg/l

0.06

0.11

0.82

<=0.2

0.20

  Fe

mg/l

0.15

0.40

0.77

<=0.5

0.50

  HCO3-

mg/l

-

-

-

<=150

150.00

  SO42-

mg/l

2,518.00

2,853.00

3,020.00

<=3,000

2,853.00

  Cl-

mg/l

16,760.00

19,020.00

20,800.00

<=20,000

19,158.75

  Br-

mg/l

59.00

68.00

72.00

<=70

70.00

  NO3-

mg/l

0.03

0.10

0.78

<=0.15

0.66

  F-

mg/l

0.80

1.10

2.00

<=1.5

1.50

  SiO2

mg/l

0.63

1.00

1.30

<=1.2

1.20

  B3-

mg/l

3.80

4.70

6.10

<=5.0

5.00

TDS

mg/l

30,833

34,500

45,100

<=35,000

35,000

Intake Sea Water Quality (Chlorophyll-a, TSS and oil and grease):

Parameter

Unit

HistoricalSeawater Data

DesignRange

Mean

95%ile

Maximum

Chlorophyll-a

µg/l

1.2

9.3

60

<=60

TSS

mg/l

18

34

127

<=60

Oil and grease

mg/l

0.4

1.7

10

<=10

TOC

mg/l

1.6

2.7

4.5

<=5

rubber joint application UNICK


TAG:  rubber joint compensator
Hits:  UpdateTime:2017-08-07 14:46:19  【Printing】  【Close】
Previous:Duckbill Installation ALZAWRAH- AJMAN  Next:Duckbill Valves for Desalination Plant
Feedback|News|Link|Member|Search|Sitemap|Admin

UNICK fittings Co., Ltd all right reserved

Tel: +86 186 3800 2879 Email: sales@unickproducts.com

Rubber Expansion Joints|Duckbill Check Valves|Dismantling Joints|Metal Expansion Joints|Metal Hose|Pinch Valves|Flap Valves

Rubber Expansion Joints|Duckbill Check Valves|Dismantling Joints|Metal Expansion Joints|Metal Hose|Pinch Valves

Powered by MetInfo 5.3.18 ©2008-2025  www.metinfo.cn